- Description
- Inquiry
Overview
MFL3100 Turbine Flow Meter is used advanced technology, to be designed as high quality, good repeatability, fast response, easy installation, widely applicable for flow rate measurement of pure liquid under 5×10-6 m2/s, which should be non-corrosive to 1Cr18Ni9Ti, 2Cr13 stainless steel, corundum A12O3, and hard alloy in closed pipe. Widely used in Tap water, pure water, alcohol; gasoline, diesel, kerosene, hydraulic oil, LPG and any pure liquid without any acid corrosion with flow viscosity under 5×10-6 m2/s.
Feature
- High Accuracy: ±1%R, ±0.5%R;0.2%R (customized)
- Wide range: DN4 to DN200; Flowrate: 0.04m3/h to 800m3/h
- Process connection; thread, flange
- Output: pulse, 4-20mA, RS485, Hart
- High signal resolution for high frequency signal(3-4Khz)
- Pulse output signal can be for totalizer control system application, without zero shift, high anti-interference
Specification
Process Fluid | pure, non-corrosive Liquid, without purity | Process Connection | Thread, Flange |
water, pure water, diesel, methanol | Sensor Materia | 304SS, 306SS, 306LSS | |
Range | 0.04m3/h to 800m3/h | Pressure Rate | 4Mpa, 6.3Mpa, 10Mpa, 16Mpa, 25Mpa |
Size | DN4 to DN40 (Thread installed) | Output | Pulse, 4-20ma, RS485, Hart protocol |
DN15 to DN200 (Flange installed) | Electrical Connector | cable directly; M20X1.5 | |
Accuracy | ±1%R, ±0.5%R; 0.2%R (customized) | Housing Material | Aluminum Alloy |
Repeatability | 0.05% to 0.2% in short time | Enclosure Class | IP65 or higher customized |
Fluid Temperature | -20 ℃to 120℃ | Explosion-proof class | ExiaII CT4 or ExdII BT6 |
Range ratio | 1:10, 1:15, 1:20 | Working T&H | -20 to 60℃ |
Power supply | +24VDC±15%, ripple<=0.5% | Storage temperature | -40 to 125℃ |
3.0 V10AH lithium battery, battery voltage: 2.0 V ~3.0 V | Atmospheric pressure | 86Kpa~106Kpa |
Order Code
Order Code: MFL3100- D50F-SNA-A1P2N | Description | |||||||||
MFL3100 | -X | -X | X | X | X | X | MFL3100 Turbine Flow Meter | |||
Indicator | -N | Without head and indicator | ||||||||
-D | With indicator | |||||||||
Size | 04 | DN4 (0.04~0.25m3/h), Extended:0.04~0.4m3/h | ||||||||
06 | DN6 (0.1~0.6m3/h), Extended: 0.06~0.6m3/h | |||||||||
10 | DN10(0.2~1.2m3/h), Extended :0.15~1.5m3/h | |||||||||
15 | DN15(0.6~6m3/h), Extended :0.4~8m3/h | |||||||||
20 | DN20(0.8~8m3/h), Extended :0.4~8m3/h | |||||||||
25 | DN25(1~10m3/h), Extended :0.5~10m3/h | |||||||||
32 | DN32(1.5~15m3/h), Extended :0.8~15m3/h | |||||||||
40 | DN40(2~20m3/h), Extended: 1~20m3/h | |||||||||
50 | DN50(4~40m3/h), Extended :2~40m3/h | |||||||||
65 | DN65(7~70m3/h), Extended :4~70m3/h | |||||||||
80 | DN80(10~100m3/h), Extended: 5~100m3/h | |||||||||
100 | DN100(20~200m3/h), Extended: 10~200m3/h | |||||||||
125 | DN125(25~250m3/h), Extended:13~250m3/h | |||||||||
150 | DN150(30~300m3/h), Extended: 15~300m3/h | |||||||||
200 | DN200(80~800m3/h), Extended:40~`800m3/h | |||||||||
Process Connection | T | Thread (DN4-DN40) | ||||||||
F | Flange (DN15-DN200) | |||||||||
Sensor Material | -S | 304SS (default) | ||||||||
-L | 316SS | |||||||||
Turbine Type | N | Standard range as above range list | ||||||||
E | Extended range as above range list | |||||||||
Output | P | Pulse output | ||||||||
A | 4-20mA output | |||||||||
R | RS485, output | |||||||||
Accuracy | -A1 | 0.5 | ||||||||
-A2 | 1.0 | |||||||||
-A3 | 0.2 (specified, long delivery time) | |||||||||
Pressure Rate | P1 | 1.6Mpa | ||||||||
P2 | 2.5Mpa | |||||||||
P3 | 4.0MPA, | |||||||||
P4 | 6.3Mpa | |||||||||
P5 | 10Mpa | |||||||||
P6 | 16Mpa | |||||||||
P7 | 25Mpa | |||||||||
Explosion-proof | N | None | ||||||||
E | ExdII BT6 |