- Description
- Inquiry
Overview
MPT910S pressure transmitter is sanitary industrial application for gauge, absolute measured with ideal solution for different range measurement, adopts advanced diffusion silicon sensor as sensitive components, digital and stable circuit, precise temperature compensation, excellent sealing and assembly to guarantee the high quality and stability, widely used in various pressure measured industry.
Feature
- High accuracy and stability: ±0.1% to ±0.2%
- Gauge, absolute pressure measured
- Range: 0 …….100Mpa
- 4-20mA, 2 wire ,0-10VDC 3 wire output
- Process connection: 2’’, 2.5’’ tri-cover
- With anti- lightning, anti-RF interference
- Digital electrical board: water-proof, dust-proof, anti-interference With reversed polarity protection and instantaneous over current and over cross-voltage protection
- 316L stainless steel diaphragm, stainless steel material suitable for various complicated environment
Specification
Electrical Connection
Order Code
MPT910S Sanitary Pressure Transmitter | ||||||||
Order Code: E.g.: MPT910S-GT101AP1SN | Description | |||||||
MPT910S- | X | X | X | X | X | X | X | MPT910S Sanitary Pressure Transmitter |
Type | G | Gauge pressure measured | ||||||
A | Absolute pressure measured | |||||||
Process Temperature | T1 | -20 to 80degC | ||||||
T2 | -20 to 120degC | |||||||
Measured Range | 01 | 0-10Kpa/ 0-0.1bar/0-100mbar | ||||||
02 | 0-20Kpa / 0-0.2bar/0-200mbar | |||||||
03 | 0-35Kpa/ 0-0.35bar/0-350mbar | |||||||
04 | 0-70Kpa/ 0-0.7bar/0-700mbar | |||||||
05 | 0-100Kpa/0-0.1Mpa/ 0-1bar | |||||||
06 | 0-160Kpa/0-0.16Mpa / 0-1.6bar | |||||||
07 | 0-250Kpa/0-0.25Mpa/0-2.5bar | |||||||
08 | 0-400kpa/0-0.4Mpa/0-4.0bar | |||||||
09 | 0-600kpa/0-0.6Mpa/0-6.0bar | |||||||
10 | 0-1Mpa/0-10bar | |||||||
11 | 0-1.6Mpa / 0-16bar | |||||||
12 | 0-2.5Mpa / 0-25bar | |||||||
13 | 0-4Mpa / 0-40bar | |||||||
14 | 0-6Mpa / 0-60bar | |||||||
15 | 0-10Mpa / 0-100bar | |||||||
16 | 0-16Mpa /0-160bar | |||||||
17 | 0-25Mpa /0-250bar | |||||||
18 | 0-40Mpa /0-400bar | |||||||
19 | 0-60Mpa /0-600bar | |||||||
20 | 0-100Mpa /0-1000bar | |||||||
Output | A | 4-20ma, 2 wire | ||||||
V | 0-10VDC, 3 wire | |||||||
R | RS485 standard Mobdus-RTU output | |||||||
Process Connection | P1 | 2’’ Tri-Cover | ||||||
P2 | 2.5’’ Tri-Cover | |||||||
X | Customized | |||||||
Electrical Connector | S | Hirschman plug | ||||||
C | direct cable, 1.0m default | |||||||
A | Air Plug | |||||||
Special Function |
N | None | ||||||
A1 | 0.1% High Accuracy | |||||||
S | Lighten surge protection | |||||||
T | Customized wide temperature compensation, such as -20 to 60 ℃. please advise the compensation range. (specially used for site with much temperature difference) | |||||||
-X | Customized |
Note:
*Please advise the cable length you required if the electrical connection is direct cable type
*Absolute pressure range only for code 03, 05 to 12
* Overpressure limit: code 01 to 04: 300%FS, code: 05 to 16:200%FS, code: 17 to 20:2005FS:150%FS
* Accuracy: code: 01 range: 0-10kpa, accuracy: 0.5%FS only. Higher 10Kpa, accuracy can be0.2%FS, 0.1%FS
* Low Pressure range: 0-100Kpa, High pressure range: 40Mpa to 100Mpa