MPT930 Exprosion proof Pressure Transmitter
Gauge ,absolute pressure measured | |
---|---|
Range: -0.1kpa…..0-0.01kpa …….100Mpa | |
4-20mA ,0-5VDC , 1-5VDC output, 2 wire | |
Diffusion silicon sensor , high quality and stability | |
316L stainless steel diaphragm material | |
Process connection: M20x1.5, 1/2’’NPT, 1/4’’NPT, G1/2’’, G1/4’’ | |
Electrical connector: cable | |
Stainless steel material suitable for various complicated environment | |
- Description
- Inquiry
Overview
MPT930 pressure transmitter is explosion-proof industrial application for gauge, absolute measured with ideal solution for different range measurement, adopts advanced diffusion silicon pressure chip as sensitive components, stable circuit, precise temperature compensation, excellent sealing and assembly to guarantee the high quality and stability, widely used in various pressure measured industry.
Feature
- High accuracy and stability: ±0.1% ,±0.2%
- Gauge, absolutepressure measured
- Range: 0-0.01Mpa …….100Mpa
- 4-20mA, 2 wire,0-10VDC 3 wire output
- Process connection: 1/2’’NPT, 1/4’’NPT, M20X1.5..
- With anti- lightning, anti-RF interference
- Electrical output: water-proof, dust-proof, anti-interference
- With reversed polarity protection and instantaneous over current and over cross-voltage protection
- 316L stainlesssteel diaphragm, stainless steel material suitable for various complicated environment
Used for:
- hydraulic, pneumatic, nature gas delivery pipe
- compressor, petroleum, metallurgy
- chemical industry process control
Specification
Measured pressure | Gauge, Absolute | Process Connector | M20X1.5, M12X1, 1/2NPT, |
Process fluid | Liquid, gas, vapor, oil | 1/4NPT; G1/2, G1/4, G1/8 | |
Range | -0.1 to 0-0.01…..1000Mpa | Diaphragm material | 316LSS |
Accuracy | ±0.2%, 0.5%F.S | Connection material | 304SS |
Stability | 0.25% %F.S per year | Body material | 304SS |
Working temperature | -20 to 85℃ | Output | 4-20mA, 2 wire; |
Compensation temperature | -10 to 70℃ | 0-5VDC,1-5VDV, 2 wire | |
Zero temperature Shift | ±1.5%FS(max.) | Electrical connector | Cable, 10meters |
Sensitive temperature Shift | ±1.5%FS(max) | ||
Overload pressures | 150%F.S | Load resistance | 4-20mA: ≥800Ω,
0-5VDC: ≥50KΩ |
Vibration resistance | 20g(20-5000HZ) | ||
Shock resistance | 100g(11ms) | EMC surge | (IEC61000-4-5)2KV |
Response time | ≤1ms (up to 90% FS) | EMC static | (IEC61000-4-2) |
Insulation resistance | 100MΩ,250VDC | contact arc: 8KV,air arc:15KV | |
Enclosure protection class | Exia II CT6, intrinsic safety | Storage temperature | -40 to 125℃ |
IP protection | IP 65 | Power supply | 12-24VDC |
Electrical Connection
Measuring Range
Order Code
MPT930 Explosion-proof Pressure Transmitter | |||||
Order Code: E.g.: MPT930-G01VP1 | Description | ||||
MPT930- | X | X | X | X | MPT930 Explosion-proof Pressure Transmitter |
Type | G | Gauge pressure | |||
A | Absolute pressure | ||||
Range |
01 | 0-10Kpa/ 0-0.1bar/0-100mbar | |||
02 | 0-20Kpa / 0-0.2bar/0-200mbar | ||||
03 | 0-35Kpa/ 0-0.35bar/0-350mbar | ||||
04 | 0-70Kpa/ 0-0.7bar/0-700mbar | ||||
05 | 0-100Kpa/0-0.1Mpa/ 0-1bar | ||||
06 | 0-160Kpa/0-0.16Mpa / 0-1.6bar | ||||
07 | 0-250Kpa/0-0.25Mpa/0-2.5bar | ||||
08 | 0-400kpa/0-0.4Mpa/0-4.0bar | ||||
09 | 0-600kpa/0-0.6Mpa/0-6.0bar | ||||
10 | 0-1Mpa/0-10bar | ||||
11 | 0-1.6Mpa / 0-16bar | ||||
12 | 0-2.5Mpa / 0-25bar | ||||
13 | 0-4Mpa / 0-40bar | ||||
14 | 0-6Mpa / 0-60bar | ||||
15 | 0-10Mpa / 0-100bar | ||||
16 | 0-16Mpa /0-160bar | ||||
17 | 0-25Mpa /0-250bar | ||||
18 | 0-40Mpa /0-400bar | ||||
19 | 0-60Mpa /0-600bar | ||||
20 | 0-100Mpa /0-1000bar | ||||
Output | V | 4-20ma, 2 wire | |||
A | 0-10VD, 3 wire | ||||
Process Connection | P1 | G1/2’’, thread | |||
P2 | 1/2’’NPT, thread | ||||
P3 | G1/4’’, thread | ||||
P4 | 1/4’’NPT, thread | ||||
P5 | M20X 15, thread | ||||
P6 | M14x1.5, thread | ||||
X | Customized |
Note:
*Please advise the cable length you required if the electrical connection is direct cable type
*Absolute pressure range only for code 03, 05 to 12
* Overpressure limit: code 01 to 04: 300%FS, code: 05 to 16:200%FS, code: 17 to 20:2005FS:150%FS
* Accuracy: code: 01 range: 0-10kpa, accuracy: 0.5%FS only. Higher 10Kpa, accuracy can be0.2%FS, 0.1%FS
* Low Pressure range: 0-100Kpa, High pressure range: 40Mpa to 100Mpa