Overview
MSC90F DIN Mounted Frequency Signal Isolator, Signal Converter frequency input, with input-output-power isolated, transmitting and isolating the frequency signal to various instruments or DCS, PLC etc control systems.
Feature
- 1 input 1 output, 1 input 2 outputs, 2 inputs 2 outputs
- Transmission accuracy (20°C): (0.2%FS+1) digit
- Temperature shift: 0.0075%FS/°C
- Power-Input-Output isolation: 1.5KVrms, 1min, 50HZ
- Input: sine wave, triangle wave, square wave
- Output: 4-20ma, 0-20ma, 0-5VDC, 1-5VDC,0-10VDC Relay output; RS485 MODBUS-RTU output
- With LCD indicator or without indicator
- Standard 35mm Rail Installation with pluggable terminals
- Size:109×116.5×18.5mm
- Independent power supply :20-32VDC, AC100-260VAC
Specification
| Type | 1 input 1 output, 1 /2input 2 outputs | Accuracy | +-0.15%FS (20℃) |
| Input Signal | sine wave, triangle wave, square wave | Temperature shift | 0.0075%/℃ |
| Amplitude more than 200mV | Isolated ability | Input-output-power 1.5KV, 1min, 50Hz | |
| Frequency Range | 0-10Khz | Insulation resistance | Input-output-power ≥100MΩ/500VDC |
| Input impendence | ≥200KΩ | Response time: | ≤1second |
| Input resolution | 0.1HZ | Power supply | AC100-265V(50-60HZ); DC24V(+-10%) |
| l Output | 4-20mA,0-10mA;0-20mA;1-5V,0-5V,0-10V | Consumption (AC100-265V) | <1.7W/(1 output); <2.2W (2 outputs) |
| Load resistance | ≤500Ω when 4-20mA,0-10mA,0-20mA | Consumption (24VDC) | <2.5W/(1 output); <3W (2 outputs) |
| ≥250KΩ when 0-5V,1-5VDC | Case material/Protection | PC/ IP20 | |
| ≥500KΩ when 0-10VDC | EMC | GB/T18268 (IEC61326-1) | |
| Relay Output | 0.6A/125VAC, 2A/30VDC | Size/N.W. | 121.2Xx108x13mm/0.14 |
| Feed Output | 24V/30mA; 12V/60mA (Max.) | N.W.: | 0.14kg |
| .RS485 Output | MODBUS-RTU Protocol | Working Temperature | -20 to 60℃ |
| Comm. Rate | 9.6kps | Working Humidity | 25% to 85%RH |
| Comm. Distance | ≤1Km for RS485 communication | Storage temperature | 40 to 80℃ |
Size (mm)

Order Code
| MSC90F: DIN Rail Mount Frequency Signal Isolator | ||||||||
| Order Code: E.g.: MSC90F-N11-F1N-NN | Description | |||||||
| MSC90F | -X | X | -X | X | X | X | X | MSC90F Frequency Signal Isolator (Hz) |
| Indicator | -N | Without indicator | ||||||
| -D | With indicator | |||||||
| Input-Output NO. | 11 | 1 Input 1 output | ||||||
| 12 | 1 input 2 output | |||||||
| Input Type | -F | Frequency input, please advise me the frequency range | ||||||
|
OUT1 |
1 | 4-20mA (default) | ||||||
| 2 | 0-10mA | |||||||
| 3 | 0-20mA | |||||||
| 4 | 0-5VDC | |||||||
| 5 | 1-5VDC | |||||||
| 6 | 0-10VDC | |||||||
| C | RS485 Output, MODBSU-RTU | |||||||
| X | Customized | |||||||
|
OUT2 |
N | None | ||||||
| 1 | 4-20ma (default) | |||||||
| 2 | 0-10mA | |||||||
| 3 | 0-20mA | |||||||
| 4 | 0-5VDC | |||||||
| 5 | 1-5VDC | |||||||
| 6 | 0-10VDC | |||||||
| L | Relay output | |||||||
| X | Customized | |||||||
| Feed Output
(Auxiliary power supply output) |
N | None | ||||||
| P1 | 12VDC auxiliary power supply, max. 60mA | |||||||
| P2 | 24VDC auxiliary power supply, max. 30mA | |||||||
| Power Supply | -N | 100-260VAC (50-60Hz) | ||||||
| -D | 24VDC | |||||||