• Description
  • Inquiry

 

Overview

MLT6300 is integrated submergible digital level transmitter, designed with high accuracy and stability diffusion silicon pressure sensor as sensitive components, high quality sealing and assembly technology, widely used for universal industrial applications for level measured with ideal solution.

 

Feature

  • Range: 0-0.5m to 0-170m
  • 4-20mA ,0-10Ma, 0-5VDC, output, 2 wire,3 wire
  • Diffusion silicon sensor, 0.2% high quality and stability
  • Polyurethane material Water-proof cable
  • Digital Indicator: 3-1/2LCD digital display, option
  • Protection: transmitter: IP68, Indicator: IP65
  • With anti- lightning, anti-RF interference
  • With reverse polarity protection and limit current protection
  • Wide power supply: 12-36VDC

 

Specification  

 

Order Code

MLT6300 Throw-in Submergible Level Transmitter
Order Code: E.g.: MLT6300-DT01ANN1-N Description
MLT6300- X X X X -X X -X MLT6300 Intelligent Throw-in Liquid Level Transmitter
Local Display -N             None, without local indicator
-D             Yes, with local LCD indicator
Installation N           None
T           Thread installation, G1’’ default, if other size, please advise thread size
F           Flange installation, please advise flange size, such as DN25, DN32…
Range           Range Accuracy

(Standard; Specified)

          Mini. Range Max. Range
01         0-0.5m 0-1.0m ±0.5%
02         0-1.0m 0-3.5m ±0.5%
03         0-3.5m 0-10m ±0.5%; ±0.2% (5m-10m)
04         0-10m 0-20m ±0.2%
05         0-20m 0-70m ±0.2%, ±0.1% (≥30m)
06         0-70m 0-170m ±0.2%, ±0.1%
07         0-100m 0-200m ±0.2%, ±0.1%
X         Customized
Output A       4-20ma, 2 wire, default
R       RS485 output, standard MODBUS-RTU protocol
AR       4-20ma +RS485 output
AH       4-20ma +HART output
Lightning Surge Protection -N     None
-S     with Lighting surge protection
Lead cable length NX   Total Cable length, same as ex-work range, please advise the range

e.g. ex-calibration range :3m, so NX=N3

LX   Total cable length: Sensor range+ external cable length, please advise the exact sensor range and total lead cable length (such as L6: 6m cable, sensor range +external cable:6m)
Specificized Function -N None
-A1 Accuracy: 0.1% (only for measured range: more than: 30m)
-A2 Accuracy: 0.2% (only for measured range: 50Kpa-100Kpa,

E.g. the measured object: Water, range: 5m to 10m)

-C customized

Notes:

1.Order code:  MLT6300-DT01ANN1-N, MLT6300 level transmitter, with local indicator, throw-in type, water-proof cable, range: 0-1.0mm, lead cable total length: 1m, output; 4-20Ma, thread installation: G1’’, total cable lenght:1m

2.Please advise me the density of the fluid in measuring statue (except water), which should be compatible with the material of the contacting part of transmitter

3. Standard Accuracy: 0-10m:0.5% standard; 10m above: 0.2% Specificized: 5-10m: 0.2% ; 30m above, accuracy: 0.1%

 