- Description
- Inquiry
Overview
MVT200 series vibration transmitter is a integrative transmitter,installed directly on the bearing cover of various rotary machine and device, widely used in various thermal power plant, cement plant,machine plant, blower plant, paper made plant, coal mine machine, be aimed to achieve high accuracy vibration measurement systems in industry applications.
Feature
- Vibration velocity ,vibration displacement measured
- 4-20mA output, 2-wire, 3-wire, loop powered
- Interface with DCS,PLC, 4-20ma monitor &device
- Process Connection: M20X1.5; 1/2’’NPT; 1/4’’NPT
- Electrical connector: air plug, water-proof plug
- Explosion-proof, water-proof house for various complicated environment
Used for:
- Steam turbine, Compressors, Motors, Blower, Fans
- Pumps, Centrifugal pump, Centrifuge
- Controlling vibration conveyor, General purpose machine
Specification
Measured vibration | Vibration velocity/displacement |
Frequency response | 5-1000HZ |
Natural frequency | 5HZ |
Vibration velocity | 0-10mm/s, 0-25mm/s,0-50mm/s |
Vibration displacement | 0-100um, 0-200um, 0-500um |
Output | 4-20mA, 3 wire; 2 wire option |
Output impedance | ≤500 ohm |
Max acceleration | 10g |
Measure direction | Vertical or horizontal directly |
Process connection | M20 X1.5; 1/2NPT; 1/4’’NPT |
Electrical connector | Air plug; water-proof ,option |
House material | Water-proof, explosion-proof case |
Working ambient | T: 30℃ to 50℃; H: ≤90% |
Size/weight | φ70x115mm/1.4kg |
House dimension | OD:70mm, ID: 57mm, H:115mm |
Power supply | 24VDC |
Size
Order Code
MVT200 Vibration Transmitter | ||||
Order Code: E.g.: MVT200-V2P11 | Description | |||
MVT200- | X | X | X | MVT200 Explosion-proof, water-proof Vibration Transmitter |
Range | -V1 | Vibration velocity : 0-10mm/s | ||
-V2 | Vibration velocity: 0-25mm/s | |||
-V 3 | Vibration velocity: 0-50mm/s | |||
-D1 | Vibration displacement: 0-100um | |||
-D2 | Vibration displacement: 0-200um | |||
-D3 | Vibration displacement: 0-500um | |||
-X | Vibration displacement: customized | |||
Process Connection | P1 | M20x1.5, (default), welding the nut on the measured point& screw on transmitter. | ||
P2 | 1/2’’NPT, welding the nut on the measured point& screw on transmitter | |||
P3 | 1/4’’NPT, welding the nut on the measured point& screw on transmitter | |||
Output | 1 | 4-20mA,3 wire (default) | ||
2 | 4-20mA,2 wire (default) |