• Description
  • Inquiry

 

Overview

MVT200 series vibration transmitter is a integrative transmitter,installed directly on the bearing cover of various rotary machine and device, widely used in various thermal power plant, cement plant,machine plant, blower plant, paper made plant, coal mine machine, be aimed to achieve high accuracy vibration measurement systems in industry applications.

 

Feature

  • Vibration velocity ,vibration displacement measured
  • 4-20mA output, 2-wire, 3-wire, loop powered
  • Interface with DCS,PLC, 4-20ma monitor &device
  • Process Connection: M20X1.5; 1/2’’NPT; 1/4’’NPT
  • Electrical connector: air plug, water-proof plug
  • Explosion-proof, water-proof house for various complicated environment

Used for:

  • Steam turbine, Compressors, Motors, Blower, Fans
  • Pumps, Centrifugal pump, Centrifuge
  • Controlling vibration conveyor, General purpose machine

 

Specification                   

Measured vibration Vibration velocity/displacement
Frequency response 5-1000HZ
Natural frequency 5HZ
Vibration velocity 0-10mm/s, 0-25mm/s,0-50mm/s
Vibration displacement 0-100um, 0-200um, 0-500um
Output 4-20mA, 3 wire; 2 wire option
Output impedance ≤500 ohm
Max acceleration 10g
Measure direction Vertical or horizontal directly
Process connection M20 X1.5; 1/2NPT; 1/4’’NPT
Electrical connector Air plug; water-proof ,option
House material Water-proof, explosion-proof case
Working ambient T: 30℃ to 50℃; H: ≤90%
Size/weight φ70x115mm/1.4kg
House dimension  OD:70mm, ID: 57mm, H:115mm
Power supply 24VDC

 

Size

 

Order Code

MVT200 Vibration Transmitter  
Order Code: E.g.: MVT200-V2P11 Description
MVT200- X X X MVT200 Explosion-proof, water-proof Vibration Transmitter
Range -V1     Vibration velocity : 0-10mm/s
-V2     Vibration velocity: 0-25mm/s
-V 3     Vibration velocity: 0-50mm/s
-D1     Vibration displacement: 0-100um
-D2     Vibration displacement: 0-200um
-D3     Vibration displacement: 0-500um
-X     Vibration displacement: customized
Process Connection P1   M20x1.5, (default), welding the nut on the measured point& screw on transmitter.
P2   1/2’’NPT, welding the nut on the measured point& screw on transmitter
P3   1/4’’NPT, welding the nut on the measured point& screw on transmitter
Output 1 4-20mA,3 wire (default)
2 4-20mA,2 wire (default)

 

Contact Us